| CISPR / EN 55011 /CNS 13803 / FCC 47 CFR Part 18 |
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement |
| CISPR / EN 55013 / CNS 13439 / AS/NZS CISPR 13 |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
| CISPR 14-1 / EN 55014-1/ CNS 13783-1 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
| CISPR 14-2 /EN 55014-2 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
| CISPR/ EN 55022 / CNS 13438 / FCC 15B |
Limits and methods of measurement of radio disturbance characteristics of information technology equipment |
| CISPR 24 / EN 55024 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
| EN 50130-4 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems |
| EN 50082-1 /EN 61000-6-1 |
Electromagnetic compatibility (EMC)
Part 6-1 : Generic standards -
Immunity for residential, commercial and
light-industrial environments
|
| EN 50081-1 /EN 61000-6-3 |
Electromagnetic compatibility (EMC) -
Part 6-3: Generic standards -
Emission standard for residential, commercial
and light-industrial environments
|
| EN 50082-2 /EN 61000-6-2 |
Electromagnetic
compatibility (EMC) -
Part 6-2: Generic standards - Immunity
for industrial environments
|
| EN 50081-2 /EN 61000-6-4 |
Electromagnetic compatibility (EMC) -
Part 6-4: Generic standards -
Emission standard for industrial environments
|
| EN 50091-2 |
Uninterruptable power systems
Part 2: EMC requirements
|
| EN 60555-2 IEC/ EN 61000-3-2 / GB 17625.1 |
Electromagnetic
compatibility (EMC)-
Part 3-2: Limits - Limits for harmonic current emissions (equipment input current k 16 A per phase)
|
| EN 60555-3 IEC/ EN 61000-3-3 |
ELECTROMAGNETIC COMPATIBILITY (EMC) -
Part 3: Limits -
Section 3: Limltatlon of voltage fluctuations and
flicker in low-voltage supply systems for equipment
with rated current r 16 A
|
| EN 61204-3 |
Low voltage power
supplies, d.c. output -
Part 3: Electromagnetic
compatibility (EMC)
|
| IEC / EN 60601-1-2 |
Medical electrical
equipment
Part 1-2: General requirements for
safety - Collateral standard:
Electromagnetic compatibility -
Requirements and tests
|
| IEC / EN 61326 |
Electrical equipment for
measurement, control and laboratory use-EMC requirements
|
| IEC / EN 61000-4-2 |
Electromagnetic compatibility (EMC)
Part 4: Testing and measurement techniques
Section 2: Electrostatic discharge immunity test
Basic EMC Publication
|
| IEC / EN 61000-4-3 |
Electromagnetic compatibility (EMC) -
Part 4-3: Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic
field immunity test
|
| IEC / EN 61000-4-4 / CNS 14676-4 |
Electromagnetic compatibility (EMC)
Part 4: Testing and measurement techniques
Section 4: Electrical fast transient immunity test
Basic EMC publication
|
| IEC / EN 61000-4-5 / CNS 14676-5 |
Electromagnetic compatibility (EMC) -- Part 4-5: Testing and measurement techniques - Surge immunity test |
| IEC / EN 61000-4-6 |
Electromagnetic compatibility (EMC)
Part 4: Testing and measurement techniques
Section 6: immunity to conducted disturbances,induced
By radio frequence fields
|
| IEC / EN 61000-4-8 |
Electromagnetic compatibility (EMC) -
Part 4-8: Testing and measurement techniques -
Power frequency magnetic field immunity test
|
| IEC / EN 61000-4-11 |
Electromagnetic compatibility (EMC) -
Part 4-1 1: Testing and measurement techniques -
Voltage dips, short interruptions and voltage variations
immunity tests
|
| IEC / EN 61000-4-12 |
Electromagnetic compatibility (EMC) -
Part 4-12:
Testing and measurement techniques -
Oscillatory waves immunity test
|